Utilize este identificador para referenciar este registo: http://hdl.handle.net/20.500.11960/3548
Registo completo
Campo DCValorIdioma
dc.contributor.authorLeão, César-
dc.contributor.authorClemente, Filipe Manuel-
dc.contributor.authorSilva, Bruno-
dc.contributor.authorPereira, Joel-
dc.contributor.authorBadicu, Georgian-
dc.contributor.authorCamões, Miguel-
dc.contributor.authorCancela, José Maria-
dc.date.accessioned2023-10-16T11:07:53Z-
dc.date.available2023-10-16T11:07:53Z-
dc.date.issued2023-06-22-
dc.identifier.citationLeão, C., Clemente, F.M., Silva, B., Pereira, J., Badicu, G., Camões, M. & Cancela, J.M.(2023). Testing the concurrent validity and reliability of a lipowise digital skinfold caliper to assess muscle mass in healthy young adults. Heliyon, 9(6). Doi: 10.1016/j.heliyon.2023.e17569pt_PT
dc.identifier.issn2405-8440 (online)-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/3548-
dc.description.abstractThe aim of this study was to assess the validity and reliability of a novel tool to assess skinfolds and to compare the muscle mass measured through dual-x-ray-absorptiometry (DXA) and estimated using the Lee equation from the values of the skinfolds and girths in a healthy young adult population. Methods: The present study followed a cross-sectional design, including 38 participants, with 27 males (22.04 ± 5.20 years) and 11 females (21.55 ± 2.39 years). The measurement protocol included a DXA evaluation, basic measurements of body mass and stature, eight skinfolds with two skinfold calipers of different brands (Harpenden and Lipowise), and three girths. The order in which the skinfold calipers were used was randomized. The muscle mass was then calculated using the formula established by Lee et al. Results: No significant differences were found between the two skinfold calipers considering all the outcomes (p > 0.05). The correlation coefficients were between 0.724 and 0.991, which suggest very-large to nearly perfect correlations. The correlations performed revealed that muscle mass estimated from DXA is nearly perfectly correlated with both muscle mass estimated from the data obtained with the Harpenden skinfold caliper (r = 0.955) and muscle mass estimated from the data obtained with the Lipowise skinfold caliper (r = 0.954). From the results, we conclude that Lipowise caliper is an accurate skinfold caliper and it can be an alternative tool for the technician that need to assess body fat or muscle mass in precise, valid and time efficient evaluation. It should be noted that the caution to use skinfold calipers interchangeable with each other when evaluating skinfolds remains a necessity and is advisable to perform the measurements with the same brand and model of skinfold caliper when the purpose is to perform follow-up assessments.pt_PT
dc.language.isoengpt_PT
dc.rightsopenAccesspt_PT
dc.subjectBody compositionpt_PT
dc.subjectAnthropometrypt_PT
dc.subjectMuscle masspt_PT
dc.subjectSkinfold caliperspt_PT
dc.titleTesting the concurrent validity and reliability of a lipowise digital skinfold caliper to assess muscle mass in healthy young adultspt_PT
dc.typearticlept_PT
dc.date.updated2023-06-27T00:37:14Z-
dc.description.version9E1A-F9DD-3EB8 | Filipe Manuel Clemente-
dc.description.versionN/A-
dc.identifier.slugcv-prod-3293067-
dc.peerreviewedyespt_PT
degois.publication.volume9(6)pt_PT
degois.publication.titleHeliyonpt_PT
dc.identifier.doi10.1016/j.heliyon.2023.e17569-
Aparece nas colecções:ESDL - Publicações indexadas à WoS/Scopus

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Testing the concurrent validity.pdf1.75 MBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.