Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11960/4572
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFernandes, Élia-
dc.contributor.authorBarros, Mário-
dc.contributor.authorPires, Preciosa-
dc.date.accessioned2025-11-24T15:46:37Z-
dc.date.available2025-11-24T15:46:37Z-
dc.date.issued2024-01-09-
dc.identifier.citationFernandes, É., Barros, M., & Pires, P. (2024). Validation of a small-scale method for determination of phosphorus in meat and meat products by molecular absorption spectroscopy. Journal of Food Measurement and Characterization, 18, 2173-2183. https://doi.org/10.1007/s11694-023-02304-wpt_PT
dc.identifier.issn2193-4134-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/4572-
dc.description.abstractThe purpose of this study was to evaluate the applicability of an alternative analytical technique to the reference method for phosphorus detection in meat and meat products established by ISO 2294:1974, revised by ISO 23776:2021. When an analytical method is modified or a new one is developed and implemented, it should be validated before being accepted for routine determinations. Furthermore, it is necessary to demonstrate that the new or alternative method has good performance characteristics in comparison with the reference method. Therefore, a comparison of the performance of the alternative and the reference method should be made. In the present study, a statistical evaluation of the calibration model of the alternative method was made with data from interlaboratory studies made in five consecutive years using fifty analyses of meat and meat products. The statistical parameters evaluated over time for the calibration curve were the y-intercept and slope; correlation and linearity; analytical limits: detection and quantification; working range; and accuracy (precision and trueness). In the interlaboratory tests, the results obtained by the alternative analytical method were compared with those obtained by the reference method, and their performance in these tests was also evaluated. The results obtained by the alternative method indicated better accuracy than the reference method due to lower relative errors, more precision, and a good trueness evaluation through lower absolute values of the z-score. The study demonstrated that the phosphorus alternative method is applicable for the determination of total phosphorus in the matrix of meat and meat products.pt_PT
dc.language.isoengpt_PT
dc.rightsopenAccesspt_PT
dc.subjectSmall-scale methodpt_PT
dc.subjectUV–Vis spectroscopypt_PT
dc.subjectReference methodpt_PT
dc.subjectPhosphoruspt_PT
dc.subjectMeatpt_PT
dc.subjectMeat productspt_PT
dc.titleValidation of a small-scale method for determination of phosphorus in meat and meat products by molecular absorption spectroscopypt_PT
dc.typearticlept_PT
dc.date.updated2025-11-24T14:57:27Z-
dc.description.version1A1B-8A8C-276D | Élia Maria Raposo Fernandes-
dc.description.versionN/A-
dc.identifier.slugcv-prod-3496264-
dc.peerreviewedyespt_PT
degois.publication.firstPage2173pt_PT
degois.publication.lastPage2183pt_PT
degois.publication.volume18pt_PT
degois.publication.titleJournal of Food Measurement and Characterizationpt_PT
dc.identifier.doi10.1007/s11694-023-02304-w-
dc.identifier.eid2-s2.0-85181892959-
Appears in Collections:CISAS - Publicações indexadas à WoS/Scopus
ESTG - Publicações indexadas à WoS/Scopus



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.