Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11960/4719
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNunes, Leonel J. R.-
dc.contributor.authorCurado, António-
dc.date.accessioned2026-03-11T12:51:03Z-
dc.date.available2026-03-11T12:51:03Z-
dc.date.issued2023-
dc.identifier.citationNunes, L. J. R., & Curado, A. (2023). High indoor Rn concentration mitigation in a heritage building: Case study analysis of the applied constructive measures. Buildings, 13(1). Artigo e136. https://doi.org/10.3390/buildings13010136pt_PT
dc.identifier.issn2075-5309-
dc.identifier.urihttp://hdl.handle.net/20.500.11960/4719-
dc.description.abstractIndoor radon (Rn) concentration is pointed out by the World Health Organization (WHO) as the second leading cause of lung cancer. Adopting mitigation measures based on ventilation procedures is an effective solution for most cases. However, the occurrence of abnormal concentrations of indoor Rn in heritage buildings, where most interventions are restricted, may lead to alternative remediation techniques. In these cases, constructive mitigation measures, such as the use of barrier membranes on the floor or specific coating mortars on the walls, can be adequate solutions. In the current investigation, two constructive measures were applied and analyzed sequentially. The preliminary long-term monitoring campaign registered extremely high indoor Rn concentration measurements. The application of a barrier membrane covering the floor of the test compartment allowed a 90% reduction in the average Rn concentration, but it nevertheless remained substantially above the recommended value of 300 Bq·m−3. Subsequently, a coating mortar was applied on the walls. The combined measures contributed to a total reduction of 94% in the average indoor Rn concentration, which remains slightly above the recommended exposure limit. Despite the verified reduction and the apparent effectiveness of the measures, it is still necessary to carry out more monitoring campaigns to test their general applicability.pt_PT
dc.language.isoengpt_PT
dc.rightsopenAccesspt_PT
dc.subjectIndoor Rn concentrationpt_PT
dc.subjectConstructive mitigation measurespt_PT
dc.subjectRn barrier membranept_PT
dc.subjectAnti-Rn slurry coatingpt_PT
dc.titleHigh indoor Rn concentration mitigation in a heritage building: Case study analysis of the applied constructive measurespt_PT
dc.typearticlept_PT
dc.peerreviewedyespt_PT
degois.publication.firstPagee136pt_PT
degois.publication.volume13pt_PT
degois.publication.issue1pt_PT
degois.publication.titleBuildingspt_PT
dc.identifier.doi10.3390/buildings13010136-
Appears in Collections:ESCE - Publicações indexadas à WoS/Scopus
ESTG - Publicações indexadas à WoS/Scopus
proMetheus - Publicações indexadas à WoS/Scopus

Files in This Item:
File Description SizeFormat 
buildings-13-00136-v2.pdf5.03 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.